FUNCTIONAL ASSESSMENT OF A STRETCH FLEXIBLE SIDEWALK ON PB-293: Comparative analysis in determining deflection

Prijzen vanaf
47,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (3)

Beschrijving

Bol The waste generated by breakage losses in the red ceramics industry is enormous, both in the production process and in construction and transportation. Recycling is one way of reducing waste. When finely ground, red ceramic waste (RCW) acquires pozzolanic properties and can partially replace Portland cement in concrete or mortar. With this in mind, this study implemented RCV in different percentages (10% and 25%) as a partial substitute for Portland cement in concrete. Three concrete compositions were analyzed: reference (without the use of RCV), with the addition of 10% RCV and with the addition of 25% RCV. The slump test was carried out on the concretes analyzed. The specimens were molded and subjected to the compressive strength test. The results obtained showed low compressive strength. When analyzing the results, satisfactory results were observed for the performance index of the PCs with 25% and 10% RCV compared to the reference. Therefore, using RCV in concrete as a partial substitute for cement proved to be a viable alternative for disposing of the waste.

Vergelijk aanbieders (3)

Shop
Prijs
Verzendkosten
Totale prijs
47,99
Gratis
47,99
Naar shop
Gratis Shipping Costs
70,61
4,23
74,84
Naar shop
4,23 Shipping Costs
70,61
4,23
74,84
Naar shop
4,23 Shipping Costs
Beschrijving (1)

The waste generated by breakage losses in the red ceramics industry is enormous, both in the production process and in construction and transportation. Recycling is one way of reducing waste. When finely ground, red ceramic waste (RCW) acquires pozzolanic properties and can partially replace Portland cement in concrete or mortar. With this in mind, this study implemented RCV in different percentages (10% and 25%) as a partial substitute for Portland cement in concrete. Three concrete compositions were analyzed: reference (without the use of RCV), with the addition of 10% RCV and with the addition of 25% RCV. The slump test was carried out on the concretes analyzed. The specimens were molded and subjected to the compressive strength test. The results obtained showed low compressive strength. When analyzing the results, satisfactory results were observed for the performance index of the PCs with 25% and 10% RCV compared to the reference. Therefore, using RCV in concrete as a partial substitute for cement proved to be a viable alternative for disposing of the waste.


Productspecificaties

Merk Our Knowledge Publishing
EAN
  • 9786630142396
Maat


Prijshistorie

* Prijshistorie bevat geen data van Amazon, Amazon Marketplace.

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
47,99
Naar shop