Human Thermal Comfort and Pressure Modeling in Automotive Seats

Prijzen vanaf
36,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol This study conducted demonstration calculations for the thermal comfort of the human body to establish an evaluation method for automobile comfort. From a medical perspective, the seated human body experiences pressure on its muscles and blood vessels, making it challenging to create a physical model that considers these effects. In this study, we clarified part of the pressure mechanism on blood vessels and showed that, under steady-state conditions, a simple mathematical formula can comprehensively study the heat load, dimensionless heat flow, and strain due to pressure on blood vessels based on structural mechanics and thermal science knowledge. I describe the methodology of comfort based on calculations confirming the correctness of the formulas and theory. Ultimately, there is room to further develop the principles of virtual work and axial blood flow, as well as room to expand. In conclusion, this method is simpler than fluid-structure coupled analysis for steady-state analysis. We intend to offer it as a tool for practitioners and clinicians.

Vergelijk aanbieders (2)

Shop
Prijs
Verzendkosten
Totale prijs
36,99
Gratis
36,99
Naar shop
Gratis Shipping Costs
45,05
Gratis
45,05
Naar shop
Gratis Shipping Costs
Beschrijving (2)
Bol

This study conducted demonstration calculations for the thermal comfort of the human body to establish an evaluation method for automobile comfort. From a medical perspective, the seated human body experiences pressure on its muscles and blood vessels, making it challenging to create a physical model that considers these effects. In this study, we clarified part of the pressure mechanism on blood vessels and showed that, under steady-state conditions, a simple mathematical formula can comprehensively study the heat load, dimensionless heat flow, and strain due to pressure on blood vessels based on structural mechanics and thermal science knowledge. I describe the methodology of comfort based on calculations confirming the correctness of the formulas and theory. Ultimately, there is room to further develop the principles of virtual work and axial blood flow, as well as room to expand. In conclusion, this method is simpler than fluid-structure coupled analysis for steady-state analysis. We intend to offer it as a tool for practitioners and clinicians.

Amazon

Pagina's: 44, Paperback, Eliva Press


Productspecificaties

Merk Eliva Press
EAN
  • 9789999329217
Maat


Prijshistorie

* Prijshistorie bevat geen data van Amazon.

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
36,99
Naar shop