Preserving Circuit Breaker Adequacy in Electric Power Systems

Prijzen vanaf
79,90

Uitgelicht


Beschrijving

Bol Power system expansions increase fault current levels. A number of circuit breakers were not designed to interrupt such increased faults currents; such breakers are said to be overstressed, underrated, or inadequate. Inadequate ratings expose overstressed breakers to increased failure probabilities. Circuit breaker failures may cause extensive common-mode outages and reduce power systems reliability. One objective of this work is to quantify the limits imposed by inadequate circuit breakers in terms of probability of failure. The other objective is to provide guidelines for network reconfigurations, generator commitment, and economic dispatch strategies. Breaker adequacy is preserved by keeping fault currents within the operating limits of overstressed breakers until such breakers are replaced. The immediate benefit of the proposed strategies is a reduction of the failure probability of overstressed breakers. Other benefits include (i) increased network reliability, (ii) restored operating margins with respect to existing equipment, and (iii) improved planning of overstressed breaker replacements that account for long-term trends in power system growth.

Vergelijk aanbieders (1)

Shop
Prijs
Verzendkosten
Totale prijs
79,90
Gratis
79,90
Naar shop
Gratis Shipping Costs
Beschrijving (1)

Power system expansions increase fault current levels. A number of circuit breakers were not designed to interrupt such increased faults currents; such breakers are said to be overstressed, underrated, or inadequate. Inadequate ratings expose overstressed breakers to increased failure probabilities. Circuit breaker failures may cause extensive common-mode outages and reduce power systems reliability. One objective of this work is to quantify the limits imposed by inadequate circuit breakers in terms of probability of failure. The other objective is to provide guidelines for network reconfigurations, generator commitment, and economic dispatch strategies. Breaker adequacy is preserved by keeping fault currents within the operating limits of overstressed breakers until such breakers are replaced. The immediate benefit of the proposed strategies is a reduction of the failure probability of overstressed breakers. Other benefits include (i) increased network reliability, (ii) restored operating margins with respect to existing equipment, and (iii) improved planning of overstressed breaker replacements that account for long-term trends in power system growth.


Productspecificaties

EAN
  • 9786208483173
Maat


Prijshistorie

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
79,90
Naar shop