Simultaneous estimation of antidiabetic drugs by HPLC

Prijzen vanaf
47,99

Uitgelicht

VERGELIJK ALLE AANBIEDERS (2)

Beschrijving

Bol A simple, precise, rapid, and reproducible reversed-phase high-performance liquid chromatography method is developed for the simultaneous estimation of metformin hydrochloride (MET), pioglitazone hydrochloride (PIO), and glimepiride (GLP) present in multicomponent dosage forms. Chromatography is carried out isocratically at 25 degrees C 0.5 degrees C on an Inertsil-ODS-3 (C-18) Column (250 x 4.60 mm, 5 microm) with a mobile phase composed of methanol-phosphate buffer (pH 4.3) in the ratio of 75:25 v/v at a flow rate of 1 mL/min. Detection is carried out using a UV-PDA detector at 258 nm. Parameters such as linearity, precision, accuracy, recovery, specificity, and ruggedness are studied as reported in the International Conference on Harmonization guidelines. The retention times for MET, PIO, and GLP are 2.66 + 0.5 min, 7.12 + 0.5 min, and 10.17 + 0.5 min, respectively. The linearity range and percentage recoveries for MET, PIO, and GLP are 10-5000, 10-150, and 1-10 microg/mL and 100.4%, 100.06%, and 100.2%, respectively. The correlation coefficients for all components are close to 1.

Vergelijk aanbieders (2)

Sorteren op:

€ 47,99 Gratis verzending

€ 124,99 Gratis verzending

Beschrijving (1)

A simple, precise, rapid, and reproducible reversed-phase high-performance liquid chromatography method is developed for the simultaneous estimation of metformin hydrochloride (MET), pioglitazone hydrochloride (PIO), and glimepiride (GLP) present in multicomponent dosage forms. Chromatography is carried out isocratically at 25 degrees C 0.5 degrees C on an Inertsil-ODS-3 (C-18) Column (250 x 4.60 mm, 5 microm) with a mobile phase composed of methanol-phosphate buffer (pH 4.3) in the ratio of 75:25 v/v at a flow rate of 1 mL/min. Detection is carried out using a UV-PDA detector at 258 nm. Parameters such as linearity, precision, accuracy, recovery, specificity, and ruggedness are studied as reported in the International Conference on Harmonization guidelines. The retention times for MET, PIO, and GLP are 2.66 + 0.5 min, 7.12 + 0.5 min, and 10.17 + 0.5 min, respectively. The linearity range and percentage recoveries for MET, PIO, and GLP are 10-5000, 10-150, and 1-10 microg/mL and 100.4%, 100.06%, and 100.2%, respectively. The correlation coefficients for all components are close to 1.


Productspecificaties

EAN
  • 9783845440446
Maat


Prijshistorie

Prijzen voor het laatst bijgewerkt op:

Uitgelichte Keuze
47,99
Naar shop